Automatic Run Modes

Turn automatic run mode functions on or off

Unit May Start Automatically!

Once automatic functions are set, the system could start at any time. Before servicing the unit, be sure to disable it to prevent injury should the unit attempt to start while servicing. All presets will remain once the battery cable is reconnected.

Automatic run mode functions can be turned on and off from the Run Mode menu. Refer to Section 5.3 (CabinTech) for configuration of the automatic run mode functions. The automatic run modes that can be configured are: • Maximum Run Time — Limits the maximum amount of time the APU can run at one time • Battery Monitor — Starts the APU when truck battery voltage drops below a set voltage • Timer 1 — The power unit and CCU are turned on automatically at the specified time and duration • Timer 2 — Second independent timer with the same functions as Timer 1 • Temp Start — Automatically turns the APU on when APU coolant temperature falls below a programmed value

Step 1: Open the Menu

From the home screen, press the MENU button.

Step 2: Select Run Mode

Rotate the dial to highlight "Run mode" and press the dial to enter.

Step 3: Choose a Function

Rotate the dial to the automatic run mode you want to change (Maximum Run Time, Battery Monitor, Timer 1, Timer 2, or Temp Start).

Step 4: Toggle On or Off

Rotate the dial to change between On and Off.

Step 5: Confirm Selection

Press the MENU button when the desired state has been selected.