Emergency Bypass Mode
Temporarily bypass a display module shutdown to protect load
If the display module fails and triggers an alarm, the unit will shut down. Emergency Bypass mode lets you temporarily override this shutdown so the unit runs normally for up to 24 hours. A countdown timer will be shown on the display. Use this time to contact the nearest Carrier Transicold Service Center for repair.
Enter Emergency Bypass Mode
With the unit in shutdown due to a display module alarm, press the MENU key until BYPASS MODE is displayed.
Press the BYPASS MODE soft key. The unit will resume normal operation for up to 24 hours.
Exit Emergency Bypass Mode
Press the MENU key until the EXIT BYPASS soft key is displayed.
Press the EXIT BYPASS soft key. The unit will shut down.
Once Emergency Bypass mode is turned off, it cannot be restarted. The unit will remain in shutdown until it is repaired. After repairs are made and the display module alarm is cleared, the unit will operate normally and Emergency Bypass mode will no longer be available.