Changing Setpoint

Change the target temperature setpoint on the X4 unit

The unit must be powered up (START/RUN-OFF switch in the START/RUN position) or in PC mode with the default screen displayed. Press the Back soft key if needed to return to the default screen.

Box temperature and setpoint on the display
Box temperature and setpoint on the display
Step 1: Adjust the Temperature

Press the UP (▲) or DOWN (▼) arrow key to change the displayed setpoint to the desired value. The setpoint changes 1° per press (or 0.1° if configured). Press and hold the key for faster scrolling — the longer you hold, the faster it changes.

Step 2: Save the Setpoint

Press the EQUALS (=) key to save the new setpoint. The MessageCenter will display "SETPOINT CHANGED" for five seconds.

Always Press EQUALS to Save!

If you do NOT press the EQUALS (=) key, after five seconds of no key activity the entire display and Light Bar will flash, the buzzer will sound for 15 seconds, and "SETPOINT NOT CHANGED" will appear. The system will then revert to the last entered setpoint. Pressing any other key while the display is flashing will stop the flashing and perform that key's function.

Setpoint Range

The default setpoint range is -22°F to +90°F (-30°C to +32°C). The APX Control System may be configured with different minimum and/or maximum values. "MAX SETPOINT HAS BEEN REACHED" or "MIN SETPOINT HAS BEEN REACHED" will display in the MessageCenter when a limit is reached.

Setpoint Memory

The APX Control System always retains the last entered setpoint in memory.

When You Cannot Change Setpoint

The setpoint cannot be changed while: • Viewing the Alarm List, Data List, or Functional Parameters • The unit is in Pre-Trip • The unit is in Sleep mode