Failed to Start - Auto Mode
engine
Description
The engine has tried to start three times unsuccessfully in Auto Start mode; engine operation shuts down and alarms, and electric operation is alarm condition only.
Activation Conditions
Engine has tried to start three times unsuccessfully in the Auto Start mode.
Unit Behavior
Engine Operation: Shutdown and alarm. Electric Operation: Alarm condition only.
Reset Conditions
Alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again. If the Configuration is set to Rail mode, this alarm will reset after 4 hours. Rail alarm reset will be recorded in the data recorder.
Corrective Actions
1. Check for Additional Alarms: If this alarm is activated in conjunction with other alarms (00040 Check Engine Preheat Circuit, 05012 Check ENCU Power Circuit, 00078 Check SV1 Circuit, 00079 Check SV4 Circuit, 05013 Check Clutch Circuit, 00085 Check UL1 Circuit or 00086 Check UL2 Circuit) check F2 and F11. Fuses must be good. Replace fuse(s) as required. Clear alarms, restart and check for repeat alarm(s). 2. Check for Low Fuel Level: Check fuel level in the fuel tank. Add fuel as needed to the fuel tank. 3. Check for Alarms: Check for the following alarms: 00040 Check Engine Preheat Circuit and 00035 Check Starter Circuit. Alarm conditions must be corrected and the alarm cleared to continue. 4. Check Engine Control Unit (ENCU) and Fuel/Speed Actuator (FSA) a. Check voltage from fuse F4 through PM-15 and SP-24 to ENCU-22. Verify correct fuse, see Figure 2.5. Must have minimum 11 VDC with the battery connected and SROS in the OFF position. b. Check voltage from PM-32 to SP-34 to ENCU-44. Must have minimum 11 VDC with SROS in the START/RUN position. If not, energize the run relay output using Component Test mode (refer to Section 5.2.4) and retest. c. Check for ground at ENCU-19 and PM-28. If ground not good, check connectors and wiring between terminals for damage, moisture or corrosion. d. Inspect fuel/speed actuator (FSA), engine speed sensor (ENSSN) and engine speed control unit (ENCU) connector pins and terminals. Verify no physical damage to components, and no damage or corrosion in connectors. e. Check resistance and amp draw of FSA. Refer to Section 2.11 for specifications. f. Check FSA plunger. Must move in and out freely. Refer to engine manual. 5. Check Engine Air-intake System a. Check air cleaner indicator. Flag must not be visible. b. Inspect air intake system. Verify hoses and tubes in good condition, with no kinks or restrictions. 6. Check for Correct Engine Oil - Check viscosity is correct for ambient conditions. Refer to Section 2.7. 7. Check Engine Exhaust System - Inspect the exhaust system. Must be clear and unobstructed. 8. Check Generator - Check for proper preventative maintenance and operating precautions. Refer to Section 8.10.12 9. Check Engine - Check engine compression. Refer to Engine Workshop manual.