05035@x4-7500low

EVXV Fault

refrigeration

Description

The MSM detected five EVXV over current events in 12 minutes, and the unit gives alarm only.

Activation Conditions

The MSM has detected five instances of EVXV over current in a 12 minute window.

Unit Behavior

Alarm only.

Reset Conditions

Auto reset when 12 minutes have gone by with no fault being detected, manual alarm reset, or cycle unit power.

Corrective Actions

Refer to P00177 for corrective actions steps.