00001@vector-8600mtmedium

Low Level Fuel Warning

fuel

Description

Fuel level is 15% or less for more than 30 seconds; engine operation gives alarm only, and electric operation will not activate this alarm.

Activation Conditions

The ENCU circuit is energized and fuel level is 15% or less for more than 30 seconds.

Unit Behavior

Engine Operation: Alarm only. Electric Operation: This alarm will not activate in electric operation.

Reset Conditions

Auto Reset when the ENCU circuit is energized and fuel level is above 17% for more than 30 seconds, or alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again. NOTE Follow the troubleshooting steps until a problem is found. Once a repair or correction is made, the active alarm should clear itself as described below. Operate the unit through the appropriate modes to see if any active alarm occurs.

Corrective Actions

1. Check For Low Fuel Level - Check fuel level in the fuel tank. Add fuel as needed to the fuel tank. 2. Check Fuel Level Sensor - Refer to procedure for alarm 00126 Check Fuel Sensor Circuit. Alarm condition must be corrected and the alarm cleared to continue.