00245@vector-8600mtmedium

Cannot Save Setting

system

Description

The unit cannot save new settings to main microprocessor memory, and it gives alarm only.

Activation Conditions

There is an error in sending and saving new settings in the main microprocessor memory.

Unit Behavior

Engine and Electric Operation: Alarm only.

Reset Conditions

Alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again.

Corrective Actions

1. Check Microprocessor Software Revision - Check microprocessor software. The unit should have the software upgraded to the latest version, provided for Carrier Transicold dealers on the Carrier Solution- Center (formerly TransCentral). 2. Reset Microprocessor a. Place the START/RUN-OFF switch in the OFF position. Disconnect positive battery cable, wait 20 seconds and reinstall. Then place the START/RUN-OFF back in the START/RUN position. The microprocessor powers up OK and the latest setpoint appears in the display. b. Check Active Alarm List. Verify alarm is cleared - microprocessor is OK. c. Alarm 00245 Cannot Save Setting remains active. Unit will operate, but changes to the settings will not be retained in the microprocessor memory. Download data and replace the Microprocessor/Stepper module (MSM) Refer to Section 5.4.