26110@vector-8700high
Engine Speed Sensor Abnormal
engine
Description
Engine speed is 0 min-1 (rpm); Engine Operation goes to Required Shutdown and Electric Operation will not activate.
Activation Conditions
Engine speed = 0 min-1 (rpm)
Unit Behavior
Engine Operation: Required Shutdown. Electric Operation: Will not activate in electric operation.
Reset Conditions
If trigger on message not received for five seconds, alarm reset or alarm may be manually reset by turning the unit off, then back on again.
Corrective Actions
Refer to Alarm 00130 Check Engine RPM Sensor.