22401@vector-8600mtmedium
MSM1 IN Low Voltage
electrical
Description
Voltage supply for the sensors on the input board is less than 4.5 VDC; the unit gives alarm only.
Activation Conditions
Voltage supply for the sensors on the input board is less than 4.5 VDC
Unit Behavior
Engine and Electric Operation: Alarm only.
Reset Conditions
Auto reset when voltage is correct, alarm reset or alarm may be manually reset by turning the unit off, then back on again.
Corrective Actions
1. Check System Pressures - Install manifold gauge set and check and compare compressor discharge, evaporator outlet & suction pressures with those shown in Unit Data. 2. Check Wiring - If a transducer reading is not within a reasonable range of gauge reading, check wires to sensors for short: 3. Replace Microprocessor/Stepper Module - Download data and replace MSM