P00143@x4-7700low

Check Clutch Circuit

electrical

Description

Clutch circuit current draw is outside the normal range, and pretrip fails in Test #2 with PRETRIP FAIL AND COMPLETED.

Activation Conditions

The circuit current draw is outside the normal range.

Unit Behavior

Pretrip will fail in Test #2 and display “PRETRIP FAIL AND COMPLETED”.

Reset Conditions

Auto reset if Pretrip is started again or Alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again.

Corrective Actions

1. Check Coil a. Inspect coil and connector pins and terminals. Verify that there is no damage to coil. Verify that there are no damaged or corroded pins. b. Check resistance of coil. Refer to Section 2.11 for specifications. c. Use Component Test mode (Refer to Section 5.2.4) to test actual current draw of the circuit. Refer to Section 2.11 for specifications. Verify that the actual current is within specifications. 2. Check Power and Wiring a. Use Component Test mode (Refer to Section 5.2.4) to energize circuit. Check for power at CLH terminal A and PM-6. Minimum 11 VDC. If not, check connectors and wiring between terminals. Verify that there is no damage, moisture or corrosion. b. Check for ground at CLH terminal B (including SP-10) to GNDRING1. Good ground. If not, check connectors and wiring between terminals. Verify that there is no damage, moisture or corrosion.