25503@x4-7700high
1-2MSM Lost Configuration
system
Description
1-2MSM Lost Configuration means the board reports an invalid configuration checksum; required shutdown.
Activation Conditions
Board reports an invalid configuration checksum
Unit Behavior
REQUIRED SHUTDOWN
Reset Conditions
Auto reset when communication is restored or alarm may be manually reset by turning the unit off, then back on again.
Corrective Actions
1. Check Wiring: Check logic power connections. 2. Replace MSM: Download data and replace Main Stepper Module. For complete Main Stepper Module replacement instructions refer to Section 5.5.2.