25101@x4-7500medium
Over Current STP1
electrical
Description
Step board 1 reports stepper current too high for three seconds, and the steppers on that board are powered off until good power is reported.
Activation Conditions
The stepper current is reported to be too high by stepper board 1 (Indicated by Stepper Output Voltage < 5V) for three seconds as timed at stepper board.
Unit Behavior
Alarm only. Steppers on board with problem disabled (Powered OFF) until good power reported from Stepper Board at which point they are re-enabled.
Reset Conditions
10 Seconds of good current range reported from all steppers.
Corrective Actions
1. Check wires: Check wiring to Stepper Valves to SVM. Verify there is no physical damage to harness, and no damage, moisture, or corrosion in connectors. 2. Check power: Check power at 2SVM-11 and 2SVM-22. Verify battery power.