25200@vector-8500high
No Comm from Micro to STP2
system
Description
No sync responses have been received from the Stepper 2 Module for 10 seconds, and the unit performs a required shutdown.
Activation Conditions
Alarm 21100 No Comm from Any Board to Main Micro is not active and No sync responses have been received from the Stepper 2 Module for 10 seconds.
Unit Behavior
Engine and Electric Operation: Required Shutdown. If alarm remains active for 2 minutes issue a shutdown command to all modules except the display.
Reset Conditions
Sync response received from the Stepper 2 Module in the past 10 seconds, alarm reset or alarm may be manually reset by turning the unit off, then back on again.
Corrective Actions
Check for 25100 No Comm from Micro to STP1 - If AL25100 is not present, it indicates the SVM Board is bad. Replace the SVM Board.