26103@vector-8500medium
Water Temp High ENCU
refrigeration
Description
Water temperature sensor voltage is 4.9 V or above; engine operation alarm only, and it will not activate in electric operation.
Activation Conditions
Voltage of water temperature sensor is 4.9 V or above
Unit Behavior
Engine Operation: Alarm only. Electric Operation: Will not activate in electric operation.
Reset Conditions
If trigger on message not received for five seconds, alarm reset or alarm may be manually reset by turning the unit off, then back on again.
Corrective Actions
Refer to: 00129 Check Engine Coolant Sensor P00155 Check Coolant Temperature Sensor