26109@x4-7700high

Actuator Abnormal ENCU

electrical

Description

Actuator current is above 3.0A or below 80mA, and the unit requires shutdown in engine operation.

Activation Conditions

Actuator current >3.0A or < 80mA

Unit Behavior

Engine Operation: Required Shutdown. Electric Operation: Will not activate in electric operation.

Reset Conditions

If trigger on message not received for five seconds, alarm reset or alarm may be manually reset by turning the unit off, then back on again.

Corrective Actions

1. Refer to 05012 Check ENCU Power Circuit 2. Check Engine Control Unit (ENCU) a. Check voltage from fuse F4 through PM-18 and SP-24 to ENCU-22. Verify correct fuse, see Figure 2.7. Must have minimum 11 VDC with the battery connected and SROS in the OFF position. b. Check voltage from PM-32 through SP-34 to ENCU-44. Must have minimum 11 VDC with SROS in the START/RUN position. If no, energize the run relay output using component test mode (refer to Section 5.2.4) and retest. c. Check for ground at ENCU-19 and PM-28 (at the battery negative cable connection). If ground not good, check connectors and wiring between terminals for damage, moisture or corrosion. d. Inspect engine speed sensor (ENSSN) and engine speed control unit (ENCU) connector pins and terminals. Verify that there is no physical damage to components, and no damage or corrosion in connectors.