27200@vector-8600mtmedium

No Comm from Micro to Comm Module

system

Description

No sync responses have been received from the Comm Module for 10 seconds under the stated conditions, and the unit alarms only.

Activation Conditions

Alarm 21100 “NO COMM FROM ANY BOARD TO MAIN MICRO” is not active, and Number Of Comm Modules Configuration is set to 1, and no sync responses have been received from the Comm Module for 10 seconds.

Unit Behavior

Engine and Electric Operation: Alarm only.

Reset Conditions

Sync response received from the Comm Module in the past 10 seconds, alarm reset or alarm may be manually reset by turning the unit off, then back on again.

Corrective Actions

1. Check for other CAN bus alarms - This alarm may accompany other alarms, complete the troubleshooting steps for alarms found. If repairs have been made and the other alarms have cleared, further troubleshooting may not be required. 2. Replace Comm Module