00210@vector-8600mtmedium

C3 Check Return Air Sensor

electrical

Description

Compartment 3 Return Air Temperature Sensor is not within -53 to +158°F (-47 to +70°C); pretrip fails and shows “PRETRIP FAIL AND COM- PLETED”.

Activation Conditions

Compartment 3 Return Air Temperature Sensor is not within the range of -53 to +158°F (- 47 to +70°C).

Unit Behavior

Engine and Electric Operation: Pretrip will fail and display “PRETRIP FAIL AND COM- PLETED”.

Reset Conditions

Auto reset if Pretrip is started again, or alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again.

Corrective Actions

Check sensor operation - Refer to procedure for alarm 00122 Check Return Air Sensor. Alarm condition must be corrected and the alarm cleared to continue.