Failed to Start โ Auto Mode
engine
Description
Diesel Engine mode only: the engine failed to start on 3 consecutive attempts, and the unit shuts down.
Activation Conditions
Not for Shore Power mode If the system is in Diesel Engine mode AND the engine fails to start on three consecutive attempts.
Unit Behavior
Required Shutdown Clear the start attempts counter and shutdown counter at the start of Pretrip Clear the shutdown counter when engine running for 15 minutes OR when normal shutoff
Reset Conditions
Alarm Reset OR Cycle Power
Corrective Actions
1. Check For Low Fuel Level - Check fuel level in the fuel tank. Add fuel as needed to the fuel tank. 2. Check For Additional Alarms a. If this alarm is activated in conjunction with other alarms (00041, 05003, and 05004) check F1 fuses must be good. Replace fuse(s) as required. Clear alarms, restart and check for repeat alarm(s). b. Check for the following alarms: 00073 CHECK ENGINE PRESTART CIRCUIT and 05000 CHECK STARTER CIRCUIT. Alarm conditions must be corrected, and the alarm cleared to continue. 3. Fuel Solenoid Test Check APU Module and Fuel Solenoid (FS) connector pins & terminals. Verify no physical damage to components, and no damage or corrosion in connectors. a. Check resistance & amp draw of FS. a. Check FS plunger. Must move in and out freely. Refer to engine manual. b. Check Engine Air-intake System c. Check air cleaner indicator. Flag must not be visible. d. Inspect air intake system. Verify hoses & tubes in good condition, with no kinks or restrictions. 4. Check For Correct Engine Oil - Check viscosity is correct for ambient conditions. Refer to Section 2.7. 5. Check Engine Exhaust System - Inspect the exhaust system. Must be clear and unobstructed. 6. Check Generator - Check for proper preventative maintenance and operating precautions. 7. Check Engine - Check engine compression. Refer to Engine Workshop manual.