00245@x4-7300low

Cannot Save Setting

system

Description

New settings cannot be sent and saved in main microprocessor memory, and the unit alarms only.

Activation Conditions

There is an error in sending and saving new settings in the main microprocessor memory.

Unit Behavior

Alarm only.

Reset Conditions

Alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again.

Corrective Actions

1. Check Microprocessor Software Revision: Check microprocessor software. Unit should have the software upgraded to the latest version, provided for Carrier Transicold dealers on the TransCentral site. 2. Reset Microprocessor a. Place the START/RUN-OFF switch in the OFF position. Disconnect positive battery cable, remove F7 fuse or unplug 1MM connector, wait 20 seconds and reinstall. Then place the START/RUN- OFF back in the START/RUN position. The microprocessor powers up OK and the latest setpoint appears in the display. b. Check Active Alarm List. Alarm is cleared: microprocessor is OK. c. If this alarm remains active, unit will operate, but changes to the settings will not be retained in the microprocessor memory. Download data and replace the main microprocessor module (MM). Refer to Section 1.5.