00019@x4-7300high

Low Fuel Shutdown

fuel

Description

Low fuel shutdown means fuel level is 10% or less for more than 30 seconds with no fuel sensor circuit alarm, and the unit alarms only or shuts down and alarms if configured.

Activation Conditions

The fuel level is 10% or less for more than 30 seconds AND Alarm 00126 Check Fuel Sensor Circuit is not active.

Unit Behavior

Alarm only or (if configured for shutdown) shutdown and alarm.

Reset Conditions

Auto reset when fuel level is above 25% for more than one minute, or alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again.

Corrective Actions

1. Check For Low Fuel Level: Add fuel as needed. 2. Check Low Fuel Level Sensor: Refer to procedure for alarm 00126 Check Fuel Sensor Circuit. Alarm condition must be corrected and the alarm cleared to continue.