25502@x4-7500medium

Check Input Voltage 1-2MSM

electrical

Description

1-MSM reports input voltage out of the 9V to 17V range for three seconds, and the steppers on that board are powered off until good power is reported.

Activation Conditions

The stepper input voltage is reported out of valid range (9V to 17V) by 1-MSM for three seconds.

Unit Behavior

Alarm only. Steppers on board with problem disabled (Powered OFF) until good power reported from Stepper Board at which point they are re-enabled.

Reset Conditions

10 Seconds of good voltage reported from all steppers.

Corrective Actions

1. Check voltages: Check input voltage at 1-2MSM-22.Check Fuse F5 a. a. Visually check fuse. Verify correct fuse and check fuse holder for damage (see Figure 2.7).Replace fuse as required. Clear alarms, restart and check for repeat alarm(s). b. Check voltage through the fuse. If fuse is blown, replace it. c. Check wiring from PM-13 to 1-2MSM-22. Verify that there is no physical damage to harness, and no damage, moisture or corrosion in connectors. 2. Disconnect Stepper Valve(s): If alarm goes away check operation of suspected valve. Refer to Section 1.9.7 / Section 1.9.8.