26211@x4-7500high
EES ECM Output Failure
electrical
Description
ECM digital outlet current is outside the acceptable range, and the unit does a required shutdown.
Activation Conditions
ECM digital outlet current is outside the acceptable range.
Unit Behavior
Required Shutdown.
Reset Conditions
If trigger on message not received for five seconds, alarm reset or alarm may be manually reset by turning the unit off, then back on again.
Corrective Actions
1. Check Fuse F10. 2. Perform manual regeneration. 3. Replace ECM if no outputs become energized.