24402@vector-8600mtmedium
Sensor Input Voltage High CCB4 (3REC-C3)
electrical
Description
Sensor input voltage on CCB4 is above 5.5V, and the unit sounds an alarm only.
Activation Conditions
The Voltage Supply for the Sensors on the CCB4 is above the high voltage limit 5.5V.
Unit Behavior
Engine and Electric Operation: Alarm Only.
Reset Conditions
The Voltage Supply for Sensors on CCB4 is below the High voltage limit 5.5V.
Corrective Actions
Check CCB3 - This alarm indicates a faulted CCB. Replace the CCB. Refer to Section 8.10.5.