25101@vector-8500medium

Over Current STP1

electrical

Description

Stepper board 1 reports too high current for 3 Seconds, and steppers on that board are powered OFF until good power is reported.

Activation Conditions

The stepper current is reported to be too high by stepper board 1 (Indicated by Stepper Output Voltage < 5V) for 3 Seconds as timed at stepper board.

Unit Behavior

Engine and Electric Operation: Alarm only. Steppers on board with problem disabled (Powered OFF) until good power reported from Stepper Board at which point they are re-enabled.

Reset Conditions

10 Seconds of good current range reported from all steppers.

Corrective Actions

1. Check wires - Check wiring to Stepper Valves to SVM. Verify there is no physical damage to harness, and no damage, moisture, or corrosion in connectors. 2. Check power - Check power at 2SVM-11 and 2SVM-22. Verify battery power.