Failed to Run Minimum Time
refrigeration
Description
The unit has shut down on an alarm too many times without running at least 15 minutes between shutdowns; engine operation shuts down the engine and unit and alarms, and electric operation shuts down refrigeration and alarms with PSCON still energized.
Activation Conditions
If Configured STANDARD: The unit has shutdown on an alarm 3 times without having run for at least 15 minutes between each shutdown (not including door switch shutdowns). If Configured RAIL: The unit has shutdown on an alarm and attempted to restart for the configured number of times without having run for at least 15 minutes between each shutdown (not including door switch shutdowns).
Unit Behavior
Engine Operation: Engine and unit shutdown and alarm. Electric Operation: Refrigeration system shutdown and alarm with PSCON still energized.
Reset Conditions
Alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again. If the Configuration is set to Rail mode, this alarm will reset after 4 hours and a rail alarm reset will be recorded in the data recorded.
Corrective Actions
Check for Alarms - Check for shutdown alarms. Alarm conditions must be corrected and the alarm(s) cleared to continue.