26221@x4-7300high

EES Frequent Regenerations

refrigeration

Description

Back pressure is above the safe regeneration threshold, so the EES entered Service mode and requires shutdown.

Activation Conditions

The back pressure is above the threshold limit where the system can safely regenerate. The EES has entered Service mode. “26201 - EES SERVICE REQUIRED” will also be active in conjunction with this alarm.

Unit Behavior

Required Shutdown.

Reset Conditions

If trigger on message not received for five seconds, alarm reset or alarm may be manually reset by turning the unit off, then back on again.

Corrective Actions

1. Remove filter and perform a manual cleaning. 2. If this alarm continues, it indicates an engine problem, check engine rings and valves. 3. “26201 - EES SERVICE REQUIRED” will also be active in conjunction with this alarm. 4. Check for other alarms in queue and inspect the EES.