P17000@vector-8600mtlow

Check EES Air Valve Control

refrigeration

Description

The air control valve is ordered to 90% closed with no engine RPM change; pretrip fails and displays “PRETRIP FAIL AND COM- PLETED”.

Activation Conditions

Air control valve has been ordered to 90% closed and there is no change in engine RPM.

Unit Behavior

Engine and Electric Operation: Pretrip will fail and display “PRETRIP FAIL AND COM- PLETED”.

Reset Conditions

Auto reset if Pretrip is started again, or alarm may be manually reset via keypad or by turning the unit off, then back on again

Corrective Actions

Check operation of the EES air control valve.