P00162@x4-7500low

Check AFA Solenoid Circuit

electrical

Description

AFAR circuit current draw is outside the normal range, and Pretrip fails and displays “PRETRIP FAIL AND COMPLETED”.

Activation Conditions

The (AFAR) circuit current draw is outside the normal range.

Unit Behavior

Pretrip will fail and display “PRETRIP FAIL AND COMPLETED”.

Reset Conditions

Auto reset if Pretrip is started again, or alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again. Dollow the steps below until a problem is found. Once a repair or correction has been made, clear the alarm(s). (Refer to Note 1 in Section 7.2) Operate the unit through the appropriate modes to see if any active alarm occurs. Continue with the steps below as necessary.

Corrective Actions

Check Relay Operation: Refer to procedure for alarm 00090 CHK AFA Solenoid Circuit. Alarm condition must be corrected and the alarm cleared to continue.