00030@vector-8600mthigh

Failed to Run Minimum Time

system

Description

The unit shut down on an alarm three times without running at least 15 minutes between shutdowns; engine operation shuts down the engine and unit with an alarm, and electric operation shuts refrigeration with PSCON energized.

Activation Conditions

If Configured STANDARD: The unit has shutdown on an alarm 3 times without having run for at least 15 minutes between each shutdown (not including door switch shutdowns).

Unit Behavior

Engine Operation: Engine and unit shutdown and alarm. Electric Operation: Refrigeration system shutdown and alarm with PSCON still energized.

Reset Conditions

Alarm may be manually reset using the display mounted keys or by turning the unit off, then back on again. If the Configuration is set to Rail mode, this alarm will reset after four hours and a rail alarm reset will be recorded in the data recorded.

Corrective Actions

Check For Alarms - Check for shutdown alarms. Alarm conditions must be corrected and the alarm(s) cleared to continue.