00015high
Battery Voltage too High
electrical
Description
Battery voltage is above safe operating range.
Activation Conditions
Battery voltage >17 VDC.
Unit Behavior
Shutdown.
Reset Conditions
Auto reset after 15 minutes when voltage is between 11-14V.
Corrective Actions
1. Check battery voltage with a multimeter. 2. Check the battery charger/alternator output โ it may be overcharging. 3. Check for loose connections.