00015high

Battery Voltage too High

electrical

Description

Battery voltage is above safe operating range.

Activation Conditions

Battery voltage >17 VDC.

Unit Behavior

Shutdown.

Reset Conditions

Auto reset after 15 minutes when voltage is between 11-14V.

Corrective Actions

1. Check battery voltage with a multimeter. 2. Check the battery charger/alternator output โ€” it may be overcharging. 3. Check for loose connections.